TA STAD Balancing Valve PN25 WM
Threaded connection. Manual Balancing valve.
DN 10-50
PN 25
- Max. working temperature: 120°C (intermittent 150°C)
- For higher temperatures (max. 150°C), see STAD-C.
- Min. working temperature: -20°C
Application:
- Heating and cooling systems
- Tap water systems
- Balancing
- Pre-setting
- Measuring
- Shut-off
- Draining (depending on valve type)
Water or neutral fluids, water-glycol mixtures (0-57%).
- Female thread according to ISO 228. Thread length according to ISO 7/1.
- Male thread according to ISO 228. Thread length according to DIN 3546.
52 158-0xx: WaterMark, IAPMO R&T OCEANA
- Max. working temperature: 120°C (intermittent 150°C)For higher temperatures (max. 150°C), see STAD-C.Min. working temperature: -20°C
- PN25
TA STAD Balancing Valve PN25 Technical specs 831.00 kb
TA STAD Balancing Valve PN25 WM
Threaded connection. Manual Balancing valve.
DN 10-50
PN 25
- Max. working temperature: 120°C (intermittent 150°C)
- For higher temperatures (max. 150°C), see STAD-C.
- Min. working temperature: -20°C
Application:
- Heating and cooling systems
- Tap water systems
- Balancing
- Pre-setting
- Measuring
- Shut-off
- Draining (depending on valve type)
Water or neutral fluids, water-glycol mixtures (0-57%).
- Female thread according to ISO 228. Thread length according to ISO 7/1.
- Male thread according to ISO 228. Thread length according to DIN 3546.
52 158-0xx: WaterMark, IAPMO R&T OCEANA
- Max. working temperature: 120°C (intermittent 150°C)For higher temperatures (max. 150°C), see STAD-C.Min. working temperature: -20°C
- PN25
TA STAD Balancing Valve PN25 Technical specs 831.00 kb
Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
Threaded connection. Manual Balancing valve.
DN 10-50
PN 25
- Max. working temperature: 120°C (intermittent 150°C)
- For higher temperatures (max. 150°C), see STAD-C.
- Min. working temperature: -20°C
Application:
- Heating and cooling systems
- Tap water systems
- Balancing
- Pre-setting
- Measuring
- Shut-off
- Draining (depending on valve type)
Water or neutral fluids, water-glycol mixtures (0-57%).
- Female thread according to ISO 228. Thread length according to ISO 7/1.
- Male thread according to ISO 228. Thread length according to DIN 3546.
52 158-0xx: WaterMark, IAPMO R&T OCEANA
- Max. working temperature: 120°C (intermittent 150°C)For higher temperatures (max. 150°C), see STAD-C.Min. working temperature: -20°C
- PN25